Shear Pin Annunciator CJX-14 For turbine guide vane shear pin break detection

Technical Specifications

Parameter Value
Operating Voltage (max) <220V AC/DC
Internal Resistance <0.2Ω
Operating Current (max) <1A
Ambient Temperature 0°C – 45°C
Relative Humidity ≤80%
Housing Material Brittle polystyrene
Types CJX (normally closed), KJX (normally open)

 

Dimensions (CJX series)

Model Diameter B (mm) Diameter C (mm) Length L (mm)
CJX-9 9 20 60
CJX-14 14 20 80
CJX-18 18 30 100
CJX-20 20 30 100
CJX-25 25 30 100
CJX-30 30 35 100

 

Product Structure

Schematic (cross-section):
Shear Pin Annunciator size
Components: Brittle polystyrene shell, internal conductive contact (normally open or normally closed), two insulated lead wires.

 

Installation & Wiring

  1. Select correct diameter (ØB) to fit shear pin center hole.
  2. Clean the axial hole inside the shear pin.
  3. Insert the annunciator fully into the hole, ensuring leads exit from the back side.
  4. Connect lead wires:
    Normally closed (CJX): connect to a compatible shear pin signal unit.
    Normally open (KJX): connect directly to alarm input (≤220V, ≤1A).
  5. Secure leads away from moving parts. Test by simulating shear pin break.

 

Safety Warnings & Precautions

  • Do not exceed rated voltage (220V) or current (1A).
  • Use only within 0–45°C and humidity ≤80%.
  • Do not hammer or force into the bore; select correct diameter.
  • For CJX type: must be used with a dedicated signal unit.
  • Replace broken annunciator – do not repair.

 

Troubleshooting & Common Faults

Fault Possible Cause Remedy
No alarm when shear pin breaks Broken internal contact, incorrect wiring, signal unit failure Check continuity; verify signal conditioner power; replace annunciator
False alarm Moisture, damaged leads, partial crack Inspect insulation; test with multimeter; replace if damaged
Annunciator does not fracture Wrong diameter (too small) Match bore diameter; reinstall correct model
High internal resistance (>0.5Ω) Corrosion or oxidation Replace annunciator

 

Packaging & Storage: Store in dry environment (-10°C to +45°C, ≤80% RH).

Ordering example: CJX-14-L80 (diameter 14mm, length 80mm).

 

 

Get a Quote